The Grundfos Hydro Multi E booster systems are specifically designed for water pressure boosting in residential, institutional, and commercial installations where there are multiple consumer outlets. These systems are complete and ready for installation, offering a comprehensive solution for boosting water pressure. Here are some applications where the Hydro Multi E booster systems can be used:
1. Residential Buildings: The Hydro Multi E booster systems are ideal for residential buildings, including apartment complexes and housing developments. They ensure consistent water pressure throughout the building, providing adequate water flow for showers, faucets, toilets, and other domestic water needs.
2. Commercial Buildings: These booster systems are suitable for various commercial settings, such as office buildings, hotels, shopping centers, and hospitals. They can handle the water demands of multiple floors, offices, rooms, and facilities, ensuring optimal water pressure for various purposes.
3. Institutional Buildings: Institutions like schools, universities, government buildings, and healthcare facilities can benefit from the Hydro Multi E booster systems. These systems provide reliable water pressure for classrooms, laboratories, restrooms, and other areas, accommodating the water needs of a large number of users.
4. Hotels and Resorts: In the hospitality industry, maintaining consistent water pressure is crucial for guest satisfaction. The Hydro Multi E booster systems can handle the water demands of hotel rooms, restaurants, spas, and other amenities, ensuring a comfortable and enjoyable experience for guests.
5. Sports Facilities: Stadiums, arenas, swimming pools, and sports complexes often require high water pressure for various purposes, including showers, irrigation, and water features. The Hydro Multi E booster systems can meet these demands, providing reliable water pressure for athletes, staff, and visitors.
6. Industrial Buildings: Certain industrial facilities require reliable water pressure for their processes and operations. The Hydro Multi E booster systems can be utilized in manufacturing plants, food processing facilities, and other industrial applications where consistent water pressure is essential.
7. Shopping Centers: Shopping malls and retail centers often have multiple restrooms, cafes, and restaurants that require adequate water pressure. The Hydro Multi E booster systems can ensure consistent water flow throughout the shopping center, catering to the needs of tenants and visitors.
8. Educational Institutions: Schools, colleges, and universities rely on proper water pressure for classrooms, laboratories, cafeterias, and other facilities. The Hydro Multi E booster systems can maintain optimal water pressure in educational institutions, facilitating a conducive learning environment.
In summary, the Grundfos Hydro Multi E booster systems are versatile solutions for water pressure boosting in residential, institutional, and commercial installations with multiple consumer outlets. Their variable speed control motors, complete with pumps, valves, sensors, diaphragm tank, and control cabinet, ensure constant output pressure regardless of the demand. These systems find applications in a wide range of settings, providing reliable water pressure for various purposes.
SYSTEM OPERATION
Sensors in the delivery pipe monitor system pressure and adjust speed to provide the demand flow at the constant pre-set pressure. Pumps operate in parallel with the second pump cutting in as demand rises thus ensuring maximum efficiency operation, extended pump life and silent running.
Systems are controlled by a controller that features digital displays on pump, as well as system operation and fault indicator lights and provides the following functions:-
- Pump sequence control ensuring that system demand is met in the most efficient way as well as an auto pump changeover to equalise operating hours.
- Dry run protection by float or pressure switch with selectable auto restart.
- Protection functions including max number of starts per hour, minimum cycle times, over pressure and motor over current.
BOSTER SET DATA
Pump |
Voltage (V) |
Power (kW) |
Nominal Flow (m3/bar) |
Set Pressure (bar) |
Tank Size (L) |
DN |
Dimensions (mm) |
Weight (kg) |
L |
H1 |
H2 |
W |
CME3 -5 |
3 X 415 |
2X1.1 |
9 |
4 |
8 |
2" |
700 |
409 |
499 |
664 |
98 |
CME3 -7 |
2X1.5 |
9 |
6 |
8 |
2" |
424 |
514 |
716 |
124 |
CME5 -4 |
2X1.5 |
13 |
4 |
18 |
2" |
431 |
514 |
663 |
127 |
CME5 -6 |
2X2.2 |
13 |
6 |
18 |
2" |
514 |
717 |
138 |
CME10-3 |
2X5.5 |
33 |
4 |
24 |
2½" |
499 |
613 |
695 |
197 |
CME10-4 |
2X5.5 |
31 |
6 |
24 |
2½" |
613 |
726 |
199 |