Victron is indeed a leading premium brand that offers high-quality Inverter Chargers engineered in the Netherlands. These versatile devices combine the functionalities of an inverter (DC to AC power conversion) and a battery charger (AC to DC power conversion) in a single unit. Victron Inverter Chargers find applications in various settings, including:
1. Off-Grid Systems: Victron Inverter Chargers are commonly used in off-grid solar power systems. They convert DC power from solar panels or batteries into AC power for running appliances, lights, and other electrical devices in remote or off-grid locations where there is no access to the utility grid.
2. Hybrid Systems: These Inverter Chargers are also suitable for hybrid solar systems, which combine solar power with a backup power source, such as a generator or the utility grid. They manage the flow of power, prioritizing solar energy while seamlessly switching to the backup source when needed.
3. Backup Power Solutions: Victron Inverter Chargers can be utilized as backup power solutions for residential, commercial, or industrial applications. They provide seamless and reliable backup power during utility grid outages, ensuring uninterrupted operation of critical loads, such as medical equipment, security systems, or refrigeration.
4. Mobile Applications: Victron Inverter Chargers are commonly used in mobile applications, such as RVs, boats, or caravans. They convert DC power from batteries or solar panels into AC power to run household appliances, entertainment systems, and charging devices while on the move.
5. Remote Telecommunication Sites: These Inverter Chargers are suitable for remote telecommunication sites or radio towers. They provide a reliable and efficient power supply, ensuring uninterrupted communication services in remote or off-grid locations.
6. Industrial Applications: Victron Inverter Chargers can be used in various industrial applications, such as remote monitoring stations, telemetry systems, or equipment powering. They provide a stable and reliable power supply for critical industrial processes in challenging environments.
7. Energy Storage Systems: These devices are commonly integrated into energy storage systems. They manage the charging and discharging of batteries, maximizing the utilization of stored energy and providing a reliable power supply when needed.
8. Grid-Interactive Systems: Victron Inverter Chargers can be used in grid-interactive systems, where solar energy is combined with the utility grid. They enable the injection of excess solar power into the grid, allowing for net metering and potential energy credits.
These applications demonstrate the versatility of Victron Inverter Chargers in various residential, commercial, industrial, and mobile settings. Their high-quality engineering, reliability, and advanced features make them a preferred choice for power conversion and backup solutions.
TECHNICAL FEATURES
Model |
MultiPlus 800VA/ 12VDC Inverter |
MultiPlus 2000VA/ 24VDC Inverter |
MultiPlus 3000VA/ 24VDC Inverter |
MultiPlus 5000VA/ 48VDC Inverter |
Quattro 8000VA/ 48VDC Inverter |
Quattro 10000VA/ 48VDC Inverter |
Easy Solar 24/3000 |
Easy Solar 48/5000 |
Output Power (VA/W) |
800/700 |
2000/1600 |
3000/2400 |
5000/4000 |
8000/6500 |
10000/8000 |
3000/2400 |
5000/4000 |
Peak Power |
1600 |
4000 |
6000 |
10000 |
16000 |
20000 |
6000 |
10000 |
DC Input Voltage (Nominal/Range) |
12VDC(9.5VDC - 17VDC) |
24VDC(19VDC - 33VDC) |
48VDC(38VDC - 66VDC) |
24VDC(19VDC - 33VDC) |
48VDC(38VDC - 66VDC) |
AC Output Voltage / Frequency (Nominal) |
230VAC/50Hz |
Output Wave |
Pure Sine wave |
Maximum Charging(A) |
35 |
50 |
70 |
110 |
140 |
70 |
Auxillary Output |
N/A |
50 |
N/A |
|
Programmable Relay |
DC Under Voltage or Genset Start/Stop Funcion, AC rating:230V/4A DC Rating: 4A upto 35VDC, 1A upto 60VDC |
Yet, set for general alarm, DC undervoltage or genset start signal function |
VE Bus Communication Bus |
For parallel and three phase operation, remote monitoring and system intergration |
For parallel & 3 phase operation, remote monitoring and system intergration |
Efficiency, Normal Mode (%) |
92 |
94 |
95 |
96 |
94 |
95 |
Unit Gross Weight (kg) |
10 |
12 |
18 |
30 |
41 |
45 |
28 |
48 |
Inverter Dimensions (HxWxD) |
375x214x110 |
520x225x125 |
362x258x218 |
444x328x240 |
470x350x280 |
470x350x280 |
810x258x218 |
877x328x241 |
Power rating @ 25°C