The Dayliff DZ self-priming waste water pumps are designed for pumping water that contains high levels of solid particles. These pumps feature a semi-open impeller axial flow design, making them suitable for various applications involving site drainage, sewage, and general effluent duties. Some applications where the Dayliff DZ pumps can be used:
1. Construction Site Drainage: The DZ pumps are commonly used for site drainage on construction sites. They can effectively handle water containing solid particles, such as mud, sand, or debris, and help remove excess water from the site, ensuring a safe and dry working environment.
2. Sewage and Wastewater Management: These pumps are suitable for sewage and wastewater applications, where they can handle water containing high solid levels. They can efficiently pump sewage or wastewater from residential, commercial, or industrial facilities to treatment plants or disposal systems.
3. Effluent Management: The Dayliff DZ pumps can be utilized for general effluent management. They are capable of handling water containing solid particles and can effectively pump effluent from various sources, such as septic tanks, processing plants, or industrial facilities, for proper disposal or treatment.
4. Flood Control and Emergency Drainage: In areas prone to flooding or during emergency situations, the DZ pumps can be deployed for flood control and emergency drainage purposes. These pumps can handle water with high solid levels and aid in rapid water removal to mitigate flooding and prevent damage to infrastructure or properties.
5. Industrial and Manufacturing Processes: The DZ pumps can be used in various industrial and manufacturing processes that generate wastewater or effluent with high solid content. They can help pump out and transfer such water for treatment, recycling, or disposal, ensuring compliance with environmental regulations.
It's essential to consider the specific requirements of each application, such as flow rate, head pressure, and the nature of solid particles, to ensure proper pump selection, installation, and maintenance. Consulting the manufacturer's guidelines and recommendations is crucial for optimal performance and longevity of the Dayliff DZ self-priming waste water pumps.
OPERATING CONDITIONS
Pumped liquid: Thin, chemically non aggressive liquids with a viscosity of up to 50mm 2/s containing suspended solids and particles up to the size indicated.
Working Liquid Temperature: -100C + 800C
Maximum Working Pressure: 6 Bar
Maximum Particle Size: 50mm
PUMP DATA
Model
|
Voltage
(V)
|
Motor
|
Speed
(rpm)
|
Max
Current (A)
|
Dimensions (mm)
|
Weight
(kg)
|
kW
|
HP
|
Intel/Outlet
|
H1
|
H2
|
L
|
W
|
DZ 40-110
|
1x240
|
1.1
|
1.5
|
2900
|
7.2
|
40
|
242
|
168
|
474
|
165
|
57
|
DZ 50-220
|
3x415
|
2.2
|
3.0
|
2900
|
4.9
|
50
|
321
|
201
|
609
|
210
|
75
|
DZ 80-400
|
3x415
|
4.0
|
5.4
|
1450
|
5.1
|
80
|
410
|
310
|
735
|
302
|
121
|