The DAYLIFF DSC split casing pumps are specifically designed for high flow applications in various sectors such as municipal water supply, irrigation, industry, and air conditioning. These pumps offer several features for reliable performance and extended service life. Here are some applications where the DAYLIFF DSC split casing pumps can be used:
1. Municipal Water Supply: The DSC pumps are suitable for municipal water supply systems that require high flow rates. They can efficiently draw water from water sources such as rivers, lakes, or reservoirs and distribute it to residential and commercial areas, ensuring a reliable and consistent water supply.
2. Irrigation Systems: These pumps are well-suited for large-scale irrigation systems, including agricultural farms, golf courses, and parks. The high flow capacity of the DSC pumps allows for effective water distribution across extensive areas, providing irrigation for crops, lawns, and landscaping.
3. Industrial Applications: The DSC split casing pumps find application in various industrial sectors that require high flow rates. They can be used in industrial processes that involve cooling systems, water circulation, or as part of HVAC systems in large industrial facilities.
4. Air Conditioning Systems: These pumps can be utilized in air conditioning systems for commercial buildings, hotels, or shopping centers. They can circulate water for cooling purposes, ensuring efficient heat transfer and maintaining optimal indoor temperatures.
5. Water Transfer: The DSC pumps are suitable for applications that involve water transfer on a large scale. They can efficiently move water from one location to another, such as transferring water between reservoirs, water treatment plants, or storage tanks.
It's important to note that the DAYLIFF DSC split casing pumps are available to special order, allowing for customization based on specific application requirements. The impeller can be trimmed to match the exact duty required, ensuring optimal performance. Additionally, different materials of construction can be selected to accommodate special applications or corrosive environments.
When considering the application of the DSC split casing pumps, it's essential to evaluate the required flow rates, head pressure, and material compatibility. Consulting with the manufacturer or an industry professional can help in selecting the appropriate pump and ensuring proper installation and integration within the system.
OPERATING PARAMETERS
Pumped Liquid: Thin, clean, chemically non aggressive liquids without solids or fibres
Max Operation Pressure: 16Bar
Max Temperature: 105°C
PUMP DATA
Model |
Max HP |
Current (A) |
Dimensions (mm) |
Weight (kg) |
DN1 |
DN2 |
a |
h |
h1 |
m |
n |
I |
DSC 80-270 |
30 |
125 |
80 |
660 |
540 |
315 |
320 |
410 |
685 |
209 |
DSC 100-375 |
55 |
150 |
100 |
740 |
640 |
355 |
320 |
470 |
685 |
245 |
DSC 125-500 |
110 |
200 |
125 |
900 |
715 |
400 |
390 |
640 |
850 |
414 |
DSC 150-605 |
250 |
200 |
150 |
1100 |
885 |
500 |
480 |
780 |
920 |
755 |
DSC 200-670 |
500 |
250 |
200 |
1200 |
920 |
600 |
500 |
800 |
1078 |
1218 |
DSC 250-600 |
630 |
300 |
250 |
1200 |
1050 |
630 |
600 |
800 |
1210 |
1116 |
DSC 300-700 |
1100 |
400 |
300 |
1400 |
1235 |
750 |
620 |
1060 |
1350 |
1640 |
DSC 350-660 |
1100 |
450 |
350 |
1400 |
1255 |
780 |
620 |
1060 |
1350 |
1900 |